On Thu, December 14, 2017 8:39 pm, Tom Van Baak wrote: > One can determine the appropriate time constant by looking at the ADEV of > the two clocks
It appears that the appropriate design would use a local oscillator which is stable to better than 10^-7 at 5 years and approximately 1200 days time constant. I would recommend using very low leakage capacitors in your RC filter. -- Chris Caudle _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.