Bruce, The link Azelio Boriani shared is the source I used when doing the same project. Please, post your results. MIne has been running for several years now without any issues. I track the OCXO control voltage register in the 2100. It has 65535 steps and over long periods (1 year) that control voltage hasn't changed. At the very beginning, it did take about 30-60 days for the control voltage to settle down. The only time I get a change is in rare situations where the unit is powered down. When it restarts it may settle into a different control voltage. I have the unit on a UPS and have backup generator for the house.
Gerhard R Wittreich, P.E. On Wed, Apr 4, 2018 at 8:29 PM, Bruce Lane <kyr...@bluefeathertech.com> wrote: > Fellow time-tickers, > > I just finished conversion of one of my TS2100's to OCXO, and I'm > now > in the process of tweaking the EEPROM settings. > > During my research, I came across (and, foolishly, didn't bookmark) > either a web page or a mailing list post which listed the 'root eng' > commands, and exactly how to enter them. I've been successful with 'root > eng ee gain' and 'root eng ee filter,' but I can't seem to get the > syntax down to set the D/A value. > > Does this sound at all familiar? > > Thanks much. > > -- > --- > Bruce Lane, ARS KC7GR > http://www.bluefeathertech.com > kyrrin (at) bluefeathertech dot com > "Quando Omni Flunkus Moritati" (Red Green) > _______________________________________________ > time-nuts mailing list -- time-nuts@febo.com > To unsubscribe, go to https://www.febo.com/cgi-bin/ > mailman/listinfo/time-nuts > and follow the instructions there. > _______________________________________________ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.