It's not necessarily a fault in the Rb physics - sometimes "regular" circuit or component problems cause the grief.

I have three units kind of like this - "SPTB-100/LN-001," to be exact, with 5 MHz out. As I recall, it's similar to the M-100, so close enough to use some of its available schematics and info. I had a problem a few years back with one that wouldn't lock, and found that a ceramic capacitor in the VCOCXO PLL filter had gone bad - leaky, so it never settled down. I could not ID the exact circuit or part because that's one of the areas that differs quite a bit from the M-100. Replacing the cap brought it back to normal operation.

I haven't searched for the "proper" manuals/schematics in a while. If anyone knows of these being available, please let me know.

Ed