In message <[email protected]>, Magnus D
anielson writes:

>> measure (start=house_std, stop=siggen) and (start=siggen, stop=house_std) for
>> as many siggen phase settings as you have patience for.
>
>Well, this was the second setup I was talking about. To disclose the
>full non-linearity you want to tweak it to 9.999 MHz rather than 10 MHz.

Yes, that is a fall-back if your siggen cannot control the phase.

Of course if you both set 9.999 MHz *and* sweep the phase, you will
be able to separte the effects of the siggen and counter even better.

-- 
Poul-Henning Kamp       | UNIX since Zilog Zeus 3.20
[email protected]         | TCP/IP since RFC 956
FreeBSD committer       | BSD since 4.3-tahoe    
Never attribute to malice what can adequately be explained by incompetence.

_______________________________________________
time-nuts mailing list -- [email protected]
To unsubscribe, go to 
http://lists.febo.com/mailman/listinfo/time-nuts_lists.febo.com