Hi,

I've been in the process of porting tinyos 1.1.15 to run on fleck3bs.
Part of what I want to port is the Deluge code. I've been able to get
programs running without Deluge. I've been able to get Deluge running up
to the point of formatting flash, inserting DelugeBasic, inserting a new
image and watching it copy across the network (I've checked the other
nodes and dumped the disseminated image and it seems to match OK.)
However, when I issue a reboot command, theres a few led flashes and
then the yellow and green leds flash rapidly forever. Resetting the
fleck boots back into the original program, so I would guess that the
new image hasn't been copied across.

I've been looking for information on what the yellow/green flash signal
means to no avail. Does anybody have any advice on what this means or
what I should be looking for?

Doug

PS Port information: fleck3bs look a lot like mica2s but with atmega
1281 processors and Nordic 905 radios. To fit the messages, I have set
DELUGE_PKT_PAYLOAD_SIZE  = 22 in Deluge.h and commented out the
uint8_t        reserved field of DelugeAdvMsg in DelugeMsg.h