Hello. On Mon, 26 Mar 2012, Oldrine Lewis wrote:
First Packet ( corrupted data) 61 88 40 22 00 FF FF 02 00 3F 08 0B 12 10 01 04 00 9A 02 07 00 27 00 00 C2 00 00 67 03 05 00
Can you read the same packet from rf230 buffer twice and compare ? (eg. to check if there is not some SPI timing problem) (or use some external LogicAnalyzer to verify communication) M.C>