> I wouldn't worry about an S-unit of noise increase, especially on 160. > > That's bound to happen with any active device like the MFJ-1025; and with > the normal BG noise level on 160, I don't think it'll keep you from hearing > anything.
Many of the DX stations I have worked for "new ones" would have been totally inaudible if my noise floor had been an S-unit higher. Both my present and former MFJ-1026 units had the high noise floor. As noted in my post about filters and IMD yesterday, the solution is to use a preamp ahead of the noise canceller. You need to feed it high enough level from the antenna such that you hear/see no increase in noise when the unit is engaged. 73, Paul N1BUG _______________________________________________ UR RST IS ... ... ..9 QSB QSB - hw? BK