Are the offending GFCI circuit breakers Eaton brand? They are known to trip from HF transmissions and it is reported that Eaton will supply "HAM" circuit breakers at no cost. I can post Eaton contact info. Some people have simply replaced the offending GFCI with standard circuit breakers.
73, Dave KH6AQ On Tue, Jan 3, 2023 at 4:56 PM <[email protected]> wrote: > GFI breakers can be finicky. If a GFI is really needed try a different > brand > breaker. > > John KK9A > > AB2E wrote: > > I trip a GFI breaker sometimes on 160m, usually in a contest 1500W. > Never had a problem when GFI outlets were the norm, but I had some > electrical work done in an added > room and the new code calls for a GFI breaker. > Has anyone had a similar experience and located an RFI resistant GFI > breaker? > 73 and HNY, > Darrell AB2E > > _________________ > Searchable Archives: http://www.contesting.com/_topband - Topband > Reflector > _________________ Searchable Archives: http://www.contesting.com/_topband - Topband Reflector