Contact info would be great Dave. Thanks in advance,
Rick Kunath, K9AO Sent from my iPad > On Jan 4, 2023, at 9:01 AM, Dave Cuthbert <[email protected]> wrote: > > Are the offending GFCI circuit breakers Eaton brand? They are known to trip > from HF transmissions and it is reported that Eaton will supply "HAM" > circuit breakers at no cost. I can post Eaton contact info. Some people > have simply replaced the offending GFCI with standard circuit breakers. > > 73, Dave KH6AQ > >> On Tue, Jan 3, 2023 at 4:56 PM <[email protected]> wrote: >> >> GFI breakers can be finicky. If a GFI is really needed try a different >> brand >> breaker. >> >> John KK9A >> >> AB2E wrote: >> >> I trip a GFI breaker sometimes on 160m, usually in a contest 1500W. >> Never had a problem when GFI outlets were the norm, but I had some >> electrical work done in an added >> room and the new code calls for a GFI breaker. >> Has anyone had a similar experience and located an RFI resistant GFI >> breaker? >> 73 and HNY, >> Darrell AB2E >> >> _________________ >> Searchable Archives: http://www.contesting.com/_topband - Topband >> Reflector >> > _________________ > Searchable Archives: http://www.contesting.com/_topband - Topband Reflector _________________ Searchable Archives: http://www.contesting.com/_topband - Topband Reflector