Stefan Berger/Watson/IBM@IBMUS wrote on 09/12/2016 11:15:34 AM:

> 
> Patch 4b68112 seems like an unlikely candidate for such a failure, 
> nevertheless that's what I am seeing: 'Could not get TPM timeouts 
> and durations'.

Actually, the patch seems to be quite broken. tpm_cmd is being read from 
after calling tpm1_getcap_cmd(), but tpm_cmd is not passed to that 
function, so it wasn't touched. I am not sure how this was intended to 
work and where the check for the returned size was going to be done.

------------------------------------------------------------------------------