Stefan Berger/Watson/IBM@IBMUS wrote on 09/12/2016 11:15:34 AM:
>
> Patch 4b68112 seems like an unlikely candidate for such a failure,
> nevertheless that's what I am seeing: 'Could not get TPM timeouts
> and durations'.
Actually, the patch seems to be quite broken. tpm_cmd is being read from
after calling tpm1_getcap_cmd(), but tpm_cmd is not passed to that
function, so it wasn't touched. I am not sure how this was intended to
work and where the check for the returned size was going to be done.
------------------------------------------------------------------------------
What NetFlow Analyzer can do for you? Monitors network bandwidth and traffic
patterns at an interface-level. Reveals which users, apps, and protocols are
consuming the most bandwidth. Provides multi-vendor support for NetFlow,
J-Flow, sFlow and other flows. Make informed decisions using capacity
planning reports. http://sdm.link/zohodev2dev
_______________________________________________
tpmdd-devel mailing list
tpmdd-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/tpmdd-devel