n0rxd wrote:
> I have the OT2m, nuvi 350 and FMI cable, all working as advertised.  But 
> occasionally, the nuvi plots a callsign with letter error (M0RXD), number 
> error (N(RXD) or loses a letter (N0RX).  These plots stay in favorites until 
> I delete them.  
> For RX, I use unsquelched audio from the radio mic connector and selected 
> software DCD in the OT2m.  I thought packets had a crc check that prevents 
> such errors. Is there a setting or command (such as kantronics PASSALL) that 
> I have set wrong?

I didn't break open the T2 documentation, but if there's a digi in your 
area that is running PASSALL (or the equivalent), your setting won't 
matter.  The digi will hear the bad packet and retransmit it with a 
"corrected" checksum making everyone that hears the digipeated packet 
believe it is correct.

Lynn (D) - KJ4ERJ