Group(s),
 
[With Mission Impossible theme song music playing in the background.]
 
I am looking for a relay that can be used without restriction for a fail
over function between CO trunks and station sets in a PBX type application.
The fail over relays switch select CO trunks over to individual phones
should the PBX fail or lose power.  The coil to contact insulation must
protect SELV from TNV-3 and the contact to contact insulation must protect
TNV-2 (which is not isolated from SELV) from TNV-3.  The internal equipment
connection schemes are cast in stone so I can't change the design to make
relay selection easier.
 
Finding relays to perform this function for the less stringent areas of the
world that only require basic insulation at 120V (or merely a 1000Vac
dielectric test) is relatively easy.  Finding relays that are small surface
mount types whose contact to contact specs meet the requirements for
supplementary insulation at 250V for Nordic countries is not.  Best I've
been able to do so far is some nice small relays (bigger than the CAD guys
would like though) that have contact to contact dielectric rated 1800Vac but
the creepage and clearance distances on the mounting pins themselves are far
below the 2.5/2.0 mm required.
 
Does anyone know of a relay that fits the bill that I have not stumbled upon
yet?
 
Thanks in advance.

-- 
Dan Roman, Compliance Engineer 
Dialogic®, an Intel Company 1515 Rt. Ten, Parsippany, NJ 07054 
* mailto:[email protected] <mailto:[email protected]>  Mail Stop:
2PY2-021 
*Voice: +1 (973) 967-6485  Fax: +1 (973) 967-8109 

 

Reply via email to