Hello Roger,
prEN 50082-1:1995 has been voted on and will be reviewed by the
CENELEC Technical Board in July. There is a proposed 4 year transition
from EN 50082-1:1992 to EN 50082-1:1995 that will begin sometime in
1997 and end in 2001. Also, prEN 50082-1:1995 makes reference to
various IEC 1000-4-x standards but is still using ENV 50140 for
Radiated Immunity and not IEC 1000-4-3.
Regards,
Ron Wellman
+============================================================+
|Ronald R. Wellman |Corporate Quality Department|
|Hewlett-Packard Company |External Product Regulations|
|Product Processes Organization |Voice : 415-857-6059 |
|1501 Page Mill Road, MS 5UL |FAX : 415-857-6340 |
|Palo Alto, California 94304 USA|E-Mail: [email protected] |
+============================================================+
| "Common sense is the collection of prejudices acquired by |
| age eighteen." - Albert Einstein |
+============================================================+
______________________________ Reply Separator _________________________________
Subject: Immunity standards
Author: Non-HP-treg-approval ([email protected]) at
HP-PaloAlto,shargw3
List-Post: [email protected]
Date: 4/24/96 2:44 PM
> Subject: Immunity standards
>
> Immunity Standards Updates:
>
> IEC 801-2 is now IEC 1000-4-2
> IEC 801-3 is now IEC 1000-4-3
> IEC 801-4 is now IEC 1000-4-4
>
> This is what I have heard anyway.
>
> Q1: Has a new EN 50082-1, Generic Immunity Standard, been > published
referencing these yet?
>
> Q2: If our product has already passed the 801-2,3,4, will we > have to
retest for the 1000-4-2,3,4 when the new Generic > Standard is published?
>
> ADVthanksANCE,
>
> roger
> [email protected]
>
> "Don't foul up my reality with your truth!"
> - ralf
>
>
>