Roger,

As far as I know, FCC Part 68 (and the Canadian equivalent, CS-03) have
always required 1000 VRMS as the test voltage for the telco interface...

- John

At 05:05 PM 11/18/96 MST, you wrote:
>Hey all,
>
>Last time I worked with a PCMCIA Card, I thought the transformers on the
>card had to be rated at about 2700 Volts. I am now looking at some new
>PCMCIA cards and it appears they are coming out with transformers rated
>at 1000-1200 Volts. Has Part 68 been changed or are these cards out
>of spec?
>
>advTHANKSance,
>
>roger
>[email protected]
>
>"Life's but a walking shadow; a poor player,
> That struts and frets his hour upon the stage,
> And then is heard no more: it is a tale
> Told by an idiot, full of sound and fury,
> Signifying nothing."
> - MacBeth, 'MacBeth', 
>     William Shakespeare
>
>
------------------------------------------------------------------
  John Combs, Senior Project Engineer, ITS/TestMark Laboratories
  Email: [email protected]          URL: http://www.testmark.com
------------------------------------------------------------------

Reply via email to