>Date: Fri, 22 Nov 96 08:57:49 PST
>From: [email protected] (Barney McNamara)
>
>I think this refers to the MLT (Metallic Loop Testing) requirements for
>BRI ISDN. I'm trying to figure out the details. It is described in Bellcore
>TR-NWT-000397, which refers to TR-TSY-000821. I am trying to decide
>whether this is required for proper operation in the US, or is it just 
>a nice thing to have?
>
>Anybody know?

We have seen a _lot_ of ISDN BRI U-interface equipment at our testing lab in
the last several years, and _none_ of it supported the NT1 Maintenance Modes.

------------------------------------------------------------------
  John Combs, Senior Project Engineer, ITS/TestMark Laboratories
  Email: [email protected]          URL: http://www.testmark.com
------------------------------------------------------------------