BS7002 is EN60950.  

 With telephone functionality, if that means acoustics, 
you're larger problem will be meeting the acoustics 
parameters.  

 Best regards, 

 Stephen 

At 02:08 PM 5/16/97 -0400, you wrote:
>Hi everybody,
>
>We are designing a modem reference board with voice
>functionality.Primarily we have targeted Europe as a market place.I 've
>been informed that for Safety;Europe is harmonised and complying with
>EN60950 was enough. Lately I  learned about some other documents like:
>
>BSI       UK               BS415/EC65 and BS7002/EC950
>VDE      Germany      VDE0884
>
>I think by complying with EN60950,you can affix CE Mark on your
>product.But what about  VDE and BSI Safety Marks?
>I got really confused.I would appreciate any help.
>
>-- 
>Thank you in advance.
>
>Filiz Eryilmaz
>MT 3K-215
>Tel:(908)9576943
>Fax:(908)9576878
>[email protected]
>
>

Reply via email to