In a message dated 97-06-03, Ron Pipes writes:

<< I'm designing a trunk interface card that must be capable of detecting
 12KHz and/or 16 KHz meter pulses. Can anyone out there point me towards
requirements or specifications with regard to meter pulse requirements. >>

Ron:

A good summary of the applicable requirements for Europe appears in chapter 9
of ETSI 300-001 (also known as NET 4).  For Australia, the requirements can
be found in clause 5.5.1.3 of TS 002.

Both of these documents are available from Compliance Engineering
(508-681-6673).  With a little extra effort, they can be obtained at lower
cost directly from ETSI and Standards Australia.

P.S.-  Did you ever work for Bell Labs in Indianapolis? 


Joe Randolph
Telecom Design Consultant
Randolph Telecom, Inc.

Reply via email to