Martin,

Look at EN 50065 series, Signaling on low-voltage electrical
installations in the frequency range 3 kHz to 148.5 kHz: Prepared
by CENELEC SC105A: Mains Communicating Systems. Here are few:

EN 50065-1  Part 1: General requirements, frequency bands
                                      and electromagnetic disturbances.

EN 50065-2  Part 2: Immunity from interference of mains
                                      communication systems on
low-voltage
                                      installations.

EN 50065-3  Part 3: Protocol and data integrity

EN 50065-4  Part 4: Filters at the interface of the indoor and
                        outdoor electricity network.

EN 50065-7  Part 7: Equipment impedance

Regards,

Mirko Matejic
The Foxboro Company
Massachusetts, USA
 ----------
From: Martin Garwood
To: [email protected]
Subject: Mains modem EN/Cenelec
List-Post: [email protected]
Date: Tuesday, September 09, 1997 6:57PM

Can anyone point me in the direction of an EN/Cenelec standard for mains
signalling modems, ie modems that communicate via mains power wiring ?

If such a standard exists, how do these products also comply with the
conducted limits of EN55022 ?

Best Regards.
 --
Martin Garwood, Manager, Austest Laboratories
4/87 Reserve Road Artarmon NSW 2064 AUSTRALIA
ph: 61-2-94374500  fax: 61-2-94374600
http://www.austest.com.au

Reply via email to