In emissions testing for compliance to FCC standards the test is required to 
be extended to 10x the highest clock in the EUT.  My system is spread spectrum 
with an in-band fundemental of 1.9GHz so for the FCC testing I have to test up 
to 20GHz.  No problem.  
However I also have to comply with the GR-1089 document.  It seem to me that if 
the EMI test is performed to 20GHz then the logical extention of that line of 
thought is that the EUT should also be tested to 20GHz for RF immunity.  
However, if I don't need to actually go to 20GHz to satisfy the BELLCORE 
requirement I surely don't want to for time and cost reasons.  Does anyone out 
there have any experiance with this or know what BELLCORE expects?

  
  RCIC - http://www.rcic.com
  Regulatory Compliance Information Center
  

Reply via email to