Hello Jim,

I do not think it is wise to use any component between phase and ground having 
a CM voltage limiting function. No component fits the requirements of EN 60950 
RELIABLE for sufficient amount of time.

I want re refer here to the requirements for solid state switches in EN 60730 
which are severe, and just for differential mode.

Especially MOV resistors tend to short circuit after a number of limiting 
actions, after a period of increasing leakage current.  

Regards,

Ing. Gert Gremmen


==
CE-test, qualified testing, 
Consultancy, Compliance tests for EMC and Electrical Safety
15 Great EMC-design tips available !
Visit our site  :  http://www.cetest.nl 
The Dutch Electronics Directory http://www.cetest.nl/electronics.htm
==


-----Oorspronkelijk bericht-----
Van:    Stewart, Judd [SMTP:[email protected]]
Verzonden:      donderdag 19 februari 1998 23:00
Aan:    'EMC-PST'
Onderwerp:      MOV's

Hello from San Diego,

Does anyone know of components that will meet the requirements of
EN60950 and also function as a MOV. The component will bridge basic
insulation in a primary circuit. 

Thanks

Judd Stewart
Litton Data Systems
619.623.6639
  • MOV's Stewart, Judd
    • RE: MOV's Ing. Gert Gremmen
    • RE: MOV's Farnsworth, Heber