Hello Jim,
I do not think it is wise to use any component between phase and ground having a CM voltage limiting function. No component fits the requirements of EN 60950 RELIABLE for sufficient amount of time. I want re refer here to the requirements for solid state switches in EN 60730 which are severe, and just for differential mode. Especially MOV resistors tend to short circuit after a number of limiting actions, after a period of increasing leakage current. Regards, Ing. Gert Gremmen == CE-test, qualified testing, Consultancy, Compliance tests for EMC and Electrical Safety 15 Great EMC-design tips available ! Visit our site : http://www.cetest.nl The Dutch Electronics Directory http://www.cetest.nl/electronics.htm == -----Oorspronkelijk bericht----- Van: Stewart, Judd [SMTP:[email protected]] Verzonden: donderdag 19 februari 1998 23:00 Aan: 'EMC-PST' Onderwerp: MOV's Hello from San Diego, Does anyone know of components that will meet the requirements of EN60950 and also function as a MOV. The component will bridge basic insulation in a primary circuit. Thanks Judd Stewart Litton Data Systems 619.623.6639