Karl,

The following type of surge is applicable for BRI. FCC uses three types of classification for ISDN Bri equipment.

For DE and DD type interface
Line Surge type A (metallic and Longitudinal)
Line Surge type B (metallic and Longitudinal)
Power line surge if applicable


For XD interface( Behind NT1)
Power line surge if applicable




>From: [email protected]
>Subject: Part 68 surge tests for ISDN BRI Equipment
>
>
>Hello Treggers,
>
>Can anybody advice me if the FCC Part 68 surge tests are applicable for
>ISDN Basic Rate devices. It seems to me that the Basic Rate Interface
>is safely separated from exposed circuits by the network terminator.
>
>Thank you in advance,
>Karl
>
>___________________________________________________________
>
> Karl-Heinz Doerfler Group Manager Compliance
> ELSA AG
> Sonnenweg 11 Phone: +49-(0)241-606-4656
> 52070 Aachen Fax: +49-(0)241-606-1199
> Germany EMail: [email protected]
>____________________________________________________________
>
>
>
>
---------------------------------------------------------------
Christopher Saleem (Senior Compl. Engr.) | |
E-mail: [email protected] | |
Phone : (408) 527-8736 ||| |||
Fax : (408) 526-8348 ||||| |||||
210 West Tasman Drive, MS SJ-F/1 ..:|||||||:...:|||||||:..
San Jose, CA 95134-1706 (U.S.A.) c i s c o S y s t e m s
-----------------------------------------------------------------