This process is already underway by IEC TC74. Refer to docujment
74/502/CD,
"Draft Technical Report, Electrical Safety; Classification of interfaces
for equipment to be connected to information and communications
technology networks." (about 30 pages)
Available from your country's IEC TC74 technical advisor.

Bob Johnson

Peter Merguerian wrote:

> Dear Group,
>
> I wish to collect information from all members regarding the various
> interfaces used in ITE and Telecommunication Equipment today
> and assignment of the following designations according to EN 60
> 950/ UL1950/ IEC 950 Standards for each interface: SELV, TNV-1,
> TNV-2, TNV-3 and Hazardous Secondary. Such interfaces can be
> data/telecom/satellite interfaces (example: RS-232, 10BaseT,
> 100BaseT, PSTN, E1/T1, ISDN S, ISDN-U, VSAT ), Remote Power
> Feeding interfaces (example: HDSL), Cental Office DC Supply,
> Wireless System Interfaces, etc. etc. Also, please assign the
> maximum dc and ac voltages involved for each interface.
>
> Once I gather all of this useful information, I plan to make a Table
> and post it to the whole group.
>
> Note that for some interfaces, such as E1/T1 the assigned "rating"
> may be either TNV-1 or SELV depending on whether the interface
> goes outside the building and subjected to overvoltages or stays
> within the building and is not subject to overvoltage. Your list
> should therefore include some notes when a circuit may have dual
> ratings depending on application. Another example is CO dc
> supplies which may be considered TNV-2 , SELV or Hazardous
> Secondary depending on country and the maximum supply voltage
> rating.
>
> I look forward to hearing from all of your safety/telecom experts out
> there. Let's help each other overcome the tremendous burden in
> evaluating separation requirements when designing equipment with
> various interfaces.
>
> Regards,
>
>
> PETER S. MERGUERIAN
> MANAGING DIRECTOR
> PRODUCT TESTING DIVISION
> I.T.L. (PRODUCT TESTING) LTD.
> HACHAROSHET 26, P.O.B. 211
> OR YEHUDA 60251, ISRAEL
>
> TEL: 972-3-5339022
> FAX: 972-3-5339019
> E-MAIL: [email protected]
> Visit our Website: http://www.itl.co.il
>
> ---------
> This message is coming from the emc-pstc discussion list.
> To cancel your subscription, send mail to [email protected]
> with the single line: "unsubscribe emc-pstc" (without the
> quotes).  For help, send mail to [email protected],
> [email protected], [email protected], or
> [email protected] (the list administrators).


---------
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to [email protected]
with the single line: "unsubscribe emc-pstc" (without the
quotes).  For help, send mail to [email protected],
[email protected], [email protected], or
[email protected] (the list administrators).

Reply via email to