On Tue, Jan 31, 2017 at 05:15:20PM -0800, Oleksandr Tymoshenko wrote: > Default fcr value is initialized in ns16550_serial_ofdata_to_platdata > but this function is only called if OF_CONTROL option is enabled while > the field is used whenever DM_SERIAL is set. So for configs that > do not have OF_CONTROL default fcr value is set to zero which leads > to loosing characters when serial port input is faster than reading > routine i.e. when copy-pasting long line to U-Boot prompt. > > As a fix initialize fcr field in probe method > > Signed-off-by: Oleksandr Tymoshenko <[email protected]> > Cc: Marek Vasut <[email protected]> > Cc: Tom Rini <[email protected]> > Cc: Simon Glass <[email protected]>
Are you still seeing this with v2017.03-rc1? Thanks! -- Tom
signature.asc
Description: Digital signature
_______________________________________________ U-Boot mailing list [email protected] http://lists.denx.de/mailman/listinfo/u-boot