Tom Rini ([email protected]) wrote:
> On Tue, Jan 31, 2017 at 05:15:20PM -0800, Oleksandr Tymoshenko wrote:
> 
> > Default fcr value is initialized in ns16550_serial_ofdata_to_platdata
> > but this function is only called if OF_CONTROL option is enabled while
> > the field is used whenever DM_SERIAL is set. So for configs that
> > do not have OF_CONTROL default fcr value is set to zero which leads
> > to loosing characters when serial port input is faster than reading
> > routine i.e. when copy-pasting long line to U-Boot prompt.
> > 
> > As a fix initialize fcr field in probe method
> > 
> > Signed-off-by: Oleksandr Tymoshenko <[email protected]>
> > Cc: Marek Vasut <[email protected]>
> > Cc: Tom Rini <[email protected]>
> > Cc: Simon Glass <[email protected]>
> 
> Are you still seeing this with v2017.03-rc1?  Thanks!

No, this bug is not reproducible on v2017.03-rc1, I believe 17fa032671
fixed it. Not sure how I missed that patch I am pretty sure I tested my
BBB with master branch.

Thanks

-- 
gonzo