On Tue, 2017-09-26 at 17:08 -0500, Dinh Nguyen wrote:
> On Tue, Sep 19, 2017 at 4:22 AM,  <chin.liang....@intel.com> wrote:
> > 
> > From: Chin Liang See <chin.liang....@intel.com>
> > 
> > Add Reset Manager driver support for Stratix SoC
> > 
> > Signed-off-by: Chin Liang See <chin.liang....@intel.com>
> > ---
> >  arch/arm/mach-socfpga/Makefile                     |   1 +
> >  arch/arm/mach-socfpga/include/mach/reset_manager.h |   2 +
> >  .../mach-socfpga/include/mach/reset_manager_s10.h  | 116
> > +++++++++++++++++
> >  arch/arm/mach-socfpga/reset_manager.c              |   5 +
> >  arch/arm/mach-socfpga/reset_manager_s10.c          | 140
> > +++++++++++++++++++++
> I don't see why you need to add a new file for S10? The functionality
> between
> Gen 5 and Stratix10 is identical for the reset manager.

Not really, they have same functions name but sequences are difference
due to diff interconnect technology. Hence, try to avoid too much #if
#else

Chin Liang

> 
> Dinh
_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
https://lists.denx.de/listinfo/u-boot