On Sat, Jan 25, 2020 at 05:52:51PM +0530, Amit Singh Tomar wrote: > Right now, Clock bindings for ethernet uses different names(even in Linux) > CLK_ETH_MAC for S900 and CLK_ETHERNET for S700, It causes compilation problem > when using them for common clock driver. > > Let's use same name CLK_ETHERNET for both S700 and S900. > > Signed-off-by: Amit Singh Tomar <[email protected]>
Reviewed-by: Manivannan Sadhasivam <[email protected]> Thanks, Mani > --- > Changes since v2: > * Newly added patch, not there in v2/v1. > --- > include/dt-bindings/clock/actions,s900-cmu.h | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) > > diff --git a/include/dt-bindings/clock/actions,s900-cmu.h > b/include/dt-bindings/clock/actions,s900-cmu.h > index 7c12515..2247f1c 100644 > --- a/include/dt-bindings/clock/actions,s900-cmu.h > +++ b/include/dt-bindings/clock/actions,s900-cmu.h > @@ -121,7 +121,7 @@ > #define CLK_DDR1 97 > #define CLK_DMM 98 > > -#define CLK_ETH_MAC 99 > +#define CLK_ETHERNET 99 > #define CLK_RMII_REF 100 > > #define CLK_NR_CLKS (CLK_RMII_REF + 1) > -- > 2.7.4 >