Hello Wolfgang,

Wolfgang Denk wrote:
> In message <1291903238-29071-1-git-send-email...@denx.de> you wrote:
>> --- a/common/cmd_dtt.c
>> +++ b/common/cmd_dtt.c
>> @@ -28,6 +28,8 @@
>>  #include <dtt.h>
>>  #include <i2c.h>
>>  
>> +static unsigned long sensors_init_done = 0;
> 
> What if there are more then 32 sensors?

Ok, that would not work ... Hmm.. I can get the number of DTTs on a board
with ARRAY_SIZE(CONFIG_DTT_SENSORS) ... should I use this info to allocate
an array, which stores the info, if the DTTs are initialized?

>>  int do_dtt (cmd_tbl_t * cmdtp, int flag, int argc, char * const argv[])
>>  {
>>      int i;
>> @@ -42,8 +44,16 @@ int do_dtt (cmd_tbl_t * cmdtp, int flag, int argc, char * 
>> const argv[])
>>       * Loop through sensors, read
>>       * temperature, and output it.
>>       */
>> -    for (i = 0; i < sizeof (sensors); i++)
>> -            printf ("DTT%d: %i C\n", i + 1, dtt_get_temp (sensors[i]));
>> +    for (i = 0; i < sizeof (sensors); i++) {
>> +            if ((sensors_init_done & (1 << i)) != (1 << i)) {
>> +                    if (dtt_init_one(sensors[i]) == 0)
>> +                            sensors_init_done |= (1 << i);
>> +                    else
>> +                            printf("DTT%d: Failed init!\n", i);
>> +            }
>> +            if ((sensors_init_done & (1 << i)) == (1 << i))
>> +                    printf ("DTT%d: %i C\n", i + 1, 
>> dtt_get_temp(sensors[i]));
>> +    }
> 
> This is overly complicated, it seems.  Why not:
> 
>       for (i = 0; i < sizeof(sensors); i++) {
>               if ((sensors_init_done & (1 << i)) == 0) {
>                       if (dtt_init_one(sensors[i]) != 0) {
>                               printf("DTT%d: init failed\n", i);
>                               continue;
>                       }
>                       sensors_init_done |= (1 << i);
>               }
> 
>               printf("DTT%d: %i C\n", i + 1, dtt_get_temp(sensors[i]));
>       }

Yep, that looks better, change this in v2.

bye,
Heiko
-- 
DENX Software Engineering GmbH,     MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
http://lists.denx.de/mailman/listinfo/u-boot

Reply via email to