Just seen various emails from Universe users about a problem with non administrator users having telnet sessions terminating, and think I may have a similar problem on Unidata 6, W2000. Our telnet parameters prompt for the path when a user logs in, if I leave the path the same the user can log in with no problems. If I change the PATH to a valid Unidata account path, the telnet process hangs on the client, and I get a 'Application popup' event on the application server.
Event Type: Information Event Source: Application Popup Event Category: None Event ID: 26 Date: 03/05/2004 Time: 10:39:05 User: N/A Computer: FL-AVANTEDB-01 Description: Application popup: udt.exe - Application Error : The instruction at "0x100408ca" referenced memory at "0x00000000". The memory could not be "read". Click on OK to terminate the program If I leave the path as the default, and then use a 'LOGTO' it works. If I change the default path in Unidata admin, it works OK. The reason I think this may be linked to the Universe problem is this only started happening on 1st May, after we loaded the patch's for the MS04-011 vulnerability. Has anyone else on W2000 with Unidata 6 seen a similar problem? Graham Forbes BT Syntegra ******************************************************************** This email may contain information which is privileged or confidential. If you are not the intended recipient of this email, please notify the sender immediately and delete it without reading, copying, storing, forwarding or disclosing its contents to any other person Thank you Check us out at http://www.btsyntegra.com ******************************************************************** ------- u2-users mailing list [EMAIL PROTECTED] http://www.u2ug.org/listinfo/u2-users