Jerry,

I haven't been able to find any reference to "flavor"  or "PICK" in the UD
documentation, so I haven't declared a flavor (as far as I know).

I would like to declare a "PICK" flavor but I don't know how to do that.

Any suggestions?

tia,

Dave

Dave Taylor
President
Sysmark Information Systems, Inc.
49 Aspen Way
Rolling Hills Estates, CA 90274
800-SYSMARK (800-797-6275)
(O) 310-544-1974
(C) 310-561-5200
(P) 800-339-1497
(F) 310-377-3550
Your Source for Integrated EDI Translation and DataSync Integration
www.sysmarkinfo.com

----- Original Message ----- 
From: "Jerry Banker" <[EMAIL PROTECTED]>
To: "Dave Taylor" <[EMAIL PROTECTED]>; <[email protected]>
Sent: Thursday, March 30, 2006 12:34 PM
Subject: Re: [U2] UD PE 7.1.0 - Use of EXECUTE with the RTNLIST option


> Flavor?
>
> ----- Original Message ----- 
> From: "Dave Taylor" <[EMAIL PROTECTED]>
> To: <[email protected]>
> Sent: Thursday, March 30, 2006 1:26 PM
> Subject: [U2] UD PE 7.1.0 - Use of EXECUTE with the RTNLIST option
>
>
> >I have had a problem compiling a program in Unidata 7.1.0 that is taken
> >from
> > Universe that uses an EXECUTE statement with the RTNLIST option.
> >
> > To test this in its simplest  form, I entered the following test program
> > and
> > got the following result after compiling it:
> >
> > ED BP TEST
> > 0001    EXECUTE "SELECT CLIENTS " RTNLIST 1
> > 0002    END
> >
> > Compiling TEST with the command BASIC BP TEST produced the following
error
> > message:
> >
> > "Misuse of reserved word 'RTNLIST'
> > Expecting: end-of-file,END
> >
> > This program appears to comply with the syntax described in the UniData
> > Commands Reference manual with the exception that it does not contain an
> > "ON
> > connection" phrase which appears to not be an option but is described as
> > "UniData no longer supports this parameter, but is remains for syntax
> > compatibility".
> >
> > Since I don't know what a "connection" is,  I tried adding X="" and the
> > phrase
> > ON X before the RTNLIST option in the EXECUTE statement and still got
the
> > same
> > error message.
> >
> > EXECUTE with the RTNLIST option works fine in Universe.
> >
> > Any suggestions?
> >
> > tia,
> >
> > Dave
> >
> > Dave Taylor
> > President
> > Sysmark Information Systems, Inc.
> > 49 Aspen Way
> > Rolling Hills Estates, CA 90274
> > 800-SYSMARK (800-797-6275)
> > (O) 310-544-1974
> > (C) 310-561-5200
> > (P) 800-339-1497
> > (F) 310-377-3550
> > Your Source for Integrated EDI Translation and DataSync Integration
> > www.sysmarkinfo.com
> > -------
> > u2-users mailing list
> > [email protected]
> > To unsubscribe please visit http://listserver.u2ug.org/
-------
u2-users mailing list
[email protected]
To unsubscribe please visit http://listserver.u2ug.org/

Reply via email to