Reflash the units with the latest firmware.  I haven't seen this
specific issue but I've seen SSH and some other random things that get
solved this way.

 

Rory

 

From: [email protected] [mailto:[email protected]]
On Behalf Of heith
Sent: Tuesday, December 9, 2014 9:02 AM
To: 'Ubiquiti Users Group'
Subject: [Ubnt_users] AirControl 2 & passwords

 

Since we have been running AC2 earlier this year, shortly after
deployment we have had several radios that would not allow access do to
a bad password. I cannot access them via web gui nor can AC2 interface
access them. If I have a customer reboot the radio or router I can
access. I have been dealing with it for about 6 months, but I have some
gear that needs updating and it's a PITA to have the call the customer
for a reboot. Majority of our stuff has the credentials changed, but
some stuff was left default on accident, and have experienced the issue
on both scenarios. 

 

Is there a new default credential when this happens? Am I doing
something wrong? If I dump AC2 will the issue go away. I never did use
AC1, only started using AC2 for mass updates & configuration changes. I
read thru the recent threads on AC2 & AC cloud, maybe I am expecting too
much for the free software

 

Thanks

Heith

 