On 1/30/2018 11:49 AM, Mike Goicoechea wrote:
> Are you using out of band management? Check eirp also. We have seen 
> the airfiber throttle down one sides power down.
I had this happen to a link, pulled it down to -26dBm TX power or 
something silly. The only fix was to manually specify the power.

For an RD-3G26 dish, I believe the max TX power should be +19dBm 
conducted; if I have done my math correctly.

-- 
-----------------------------------------------
-  Nick Bright                                -
-  Vice President of Technology               -
-  Valnet -=- We Connect You -=-              -
-  Tel 888-332-1616 x 315 / Fax 620-331-0789  -
-  Web http://www.valnet.net/                 -
-----------------------------------------------
- Are your files safe?                        -
- Valnet Vault - Secure Cloud Backup          -
- More information & 30 day free trial at     -
- http://www.valnet.net/services/valnet-vault -
-----------------------------------------------

_______________________________________________