Public bug reported:
[Impact]
There's a high chance that MT7921 BT may go out to lunch after reboot.
Worse, there's no way to recover the controller unless the power cord is
unplugged.
[Fix]
In addition to SRU "Need to reset MT7921 BT when the firmware hang or
command no response", enable MSFT extension can magically solve the
issue.
[Test]
With the patch applied, the MT7921 BT continues to work after 100 times
reboots.
[Where problems could occur]
This fix is specific to MTK BT controllers, so the change is limited.
I totally don't understand why this patch can fix the issue, other than
it just does the trick. So I guess we have to accept the reality that
hardwares can have their own quirks.
** Affects: hwe-next
Importance: Undecided
Status: New
** Affects: linux-oem-5.14 (Ubuntu)
Importance: Undecided
Status: Invalid
** Affects: linux-oem-5.14 (Ubuntu Focal)
Importance: Medium
Status: Confirmed
** Tags: oem-priority originate-from-1961591 sutton
** Also affects: linux-oem-5.14 (Ubuntu Focal)
Importance: Undecided
Status: New
** Changed in: linux-oem-5.14 (Ubuntu Focal)
Status: New => Confirmed
** Changed in: linux-oem-5.14 (Ubuntu Focal)
Importance: Undecided => Medium
** Changed in: linux-oem-5.14 (Ubuntu)
Status: New => Invalid
** Tags added: oem-priority originate-from-1961591 sutton
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1966497
Title:
Fix non-working MT7921 BT after reboot
To manage notifications about this bug go to:
https://bugs.launchpad.net/hwe-next/+bug/1966497/+subscriptions
--
ubuntu-bugs mailing list
[email protected]
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs