I checked the attached logs.

For config_B (locally built test kernel), the after-replug dmesg does
not show the same fatal NVMe failure seen in config_A. In
config_B/3-config_B.after_replug.log/dmesg3.log, all three replugged
NVMe devices probe and complete queue setup:

10000:01:00.0 -> nvme0, queues ready at line 3611
10000:02:00.0 -> nvme1, queues ready at line 3615
10000:03:00.0 -> nvme2, queues ready at line 3660

So based on the attached dmesg, the locally built test kernel does not
reproduce the same NVMe probe/reset/resource-clobbering failure as
config_A. If the failure is still seen from userspace, please provide
lsblk/nvme list before unplug and after replug, plus any I/O error
output.

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/2148638

Title:
  ubuntu 26.04 - When the NVME hard drives were hot-swapped, the OS
  reported an error and some of the drives were not recognized.

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/linux/+bug/2148638/+subscriptions


-- 