On 10/Apr/15 22:26, Nick Hilliard wrote:
>
> If you want actual resiliency at a reasonable cost point, get multiple
> unprotected waves from different providers and run bfd + mpls FRR.
> Protected circuits are a relic from a bygone era with increasingly little
> relevance in today's networks.

This.

Protection is a very SDH/SONET thing, although it can also be
implemented for EoDWDM.

We always take unprotected linear circuits and let the routers do their
thing.

Mark.