On 10/Apr/15 22:26, Nick Hilliard wrote: > > If you want actual resiliency at a reasonable cost point, get multiple > unprotected waves from different providers and run bfd + mpls FRR. > Protected circuits are a relic from a bygone era with increasingly little > relevance in today's networks.
This. Protection is a very SDH/SONET thing, although it can also be implemented for EoDWDM. We always take unprotected linear circuits and let the routers do their thing. Mark.