Pleur-Evac qui possede une poche lateral optionnel
pour le recueil de l'hemothorax et la perfusion (n'est
pas sur cette image)
http://monsite.ifrance.com/drainage/pleurevac.htm

genzyme doit le distribuer au quebec
http://www.genzymebiosurgery.com/prod/cardio/gzbx_p_pt_cardio.asp

patrick miroux
> -------------------------------------------
> De : [EMAIL PROTECTED] de la part de Charles
> Brault[SMTP:[EMAIL PROTECTED]
> Date d'envoi : dimanche 26 septembre 2004 19:35:53
> � : [EMAIL PROTECTED]
> Objet : URG-L: Kit d'autotransfusion pour r�gions
> �loign�s
> Transf�r� automatiquement par une r�gle
> 
> 
> O.K.
> 
> Je compte surtout sur l'exp�rience de nos Docs
> Franco-Fran�ais
> 
> 
> Quel sorte de kit d'auto-transfusion vous
> monteriez-vous
> Pour une petite clinique � 400 Km de St-Linlin de la
> circonspection
> !?
> 
> Vous auriez de la docu. int�ressante sur le sujet ?
> 
> 
> En vous remerciant d'avance
> 
> 
> Charles
>  - - - -
> Chest, Vol 93, 522-526, 
> Copyright � 1988 by American College of Chest
> Physicians 
> 
> Prehospital autotransfusion in life-threatening
> hemothorax
> P Barriot, B Riou and P Viars 
> 
> Service de Sante de la Brigade des Sapeurs Pompiers
> de Paris, France.
> 
> Eighteen patients with life-threatening traumatic
> hemothorax received
> prehospital autotransfusion using a simple new
> device. During
> transfer to the hospital, they received 3.9 +/- 0.5
> L of colloid
> fluid and 4.1 +/- 0.6 L of autotransfused blood,
> without
> anticoagulation. 
> Hemorrhagic blood was not coagulable, had a
> hematocrit of 20 +/- 4
> percent, few platelets, and low fibrinogen levels. 
> 
> Five patients died from irreversible hemorrhagic
> shock. 
> 
> Thirteen patients were alive upon admission to the
> hospital,
> underwent emergency surgery, and were discharged
> alive. 
> 
> During autotransfusion, 
> hematocrit decreased from 24 +/- 3 to 19 +/- 3
> percent, 
> and systolic arterial pressure increased 
> from 78 +/- 11 to 88 +/- 12 mm Hg. 
> 
> Upon admission to the hospital, 
> platelet count was 90,800 +/- 21,400/cu mm, 
> prothrombin time 48 +/- 3 percent, 
> partial thromboplastin time 197 +/- 18 percent, 
> plasma free hemoglobin levels 21 +/- 7 mg/100 ml, 
> and serum potassium levels 3.6 +/- 0.5 mmol/L. 
> 
> No serious complication could be related to
> autotransfusion
> considered to be crucial to patients' survival. The
> preliminary
> results of this study suggest that autotransfusion
> might be developed
> in the prehospital setting since it appears simple
> and safe, and
> represents the only hope of survival for patients
> with
> life-threatening hemothorax. 
> 
> --- URG-L
> Pour quitter URG-L, envoyez un message a la liste
> ([EMAIL PROTECTED]) 
> avec, COMME SUJET, le mot REMOVE (rien d'autre).
> 
>  


        

        
                
Vous manquez d�espace pour stocker vos mails ? 
Yahoo! Mail vous offre GRATUITEMENT 100 Mo !
Cr�ez votre Yahoo! Mail sur http://fr.benefits.yahoo.com/

Le nouveau Yahoo! Messenger est arriv� ! D�couvrez toutes les nouveaut�s pour 
dialoguer instantan�ment avec vos amis. A t�l�charger gratuitement sur 
http://fr.messenger.yahoo.com

--- URG-L
Les archives de la liste d'echange sont disponibles pour consultation 
a l'adresse :
<http://www.mail-archive.com/[EMAIL PROTECTED]>

Répondre à