Hi all, I have this problem in a stream pipeline using the runner Apache Flink 1.19. I want to do an upgrade to my job. I first end the job by using the Flink API creating a savepoint, and then I start the new version by using the Flink API passing the savepoint path.
When the job ends two new records are created. The first one is OK but the second one is an empty record. My pipeline uses this window strategy: *Window<KV<String, TaggedEvent>> window =* * Window.<KV<String, TaggedEvent>>into(CalendarWindows.days(this.options.getWindowDays()))* * .triggering(AfterWatermark.pastEndOfWindow()* * .withEarlyFirings(AfterProcessingTime.pastFirstElementInPane().plusDelayOf(delay))* * .withLateFirings(AfterProcessingTime.pastFirstElementInPane()))* * .withAllowedLateness(Duration.standardSeconds(this.options.getAllowedLateness()))* * .accumulatingFiredPanes();* I implemented a custom combiner, and I realized that the state of the combiner is null in the second output. This line ( https://github.com/apache/beam/blob/v2.24.0/runners/flink/src/main/java/org/apache/beam/runners/flink/translation/wrappers/streaming/state/FlinkStateInternals.java#L507) is evaluated to false, and then it creates an empty accumulator. Is this the expected behavior? Thanks