Thanks a lot Kostas. This solved my problem. Thanks and Regards,Piyush 
Shrivastava
http://webograffiti.com
 

    On Monday, 25 April 2016 3:27 PM, Kostas Kloudas 
<k.klou...@data-artisans.com> wrote:
 

 Hi,
Let me also add that you should also override the clear() method in order to 
clear you state.and delete the pending timers.
Kostas

On Apr 25, 2016, at 11:52 AM, Kostas Kloudas <k.klou...@data-artisans.com> 
wrote:

Hi Piyush,
In the onElement function, you register a timer every time you receive an 
element. 
When the next watermark arrives, in the flag==false case, this will lead to 
every element adding a timer for its timestamp+60000ms. The same for flag==true 
case, with 20000ms interval.
What you can try is to set only once, at the first element the initial trigger 
for 60 sec, and then just set all the rest in the on the onEventTime with 20 
sec.
To have a look at a custom trigger you can look at 
here:https://github.com/kl0u/flink-examples/blob/master/src/main/java/com/dataartisans/flinksolo/beam_comparison/customTriggers/EventTimeTriggerWithEarlyAndLateFiring.java
I hope this helped.Let me know if you need any help.
Kostas

On Apr 25, 2016, at 11:22 AM, Piyush Shrivastava <piyush...@yahoo.co.in> wrote:
Hi all,I want to implement a custom Trigger which fired a GlobalWindow in 1 
minute for the first time and every 20 seconds after that.I believe I cannot 
get this logic right in the implementation of my custom Trigger. Please help me 
with this.
Here is the code of my custom Trigger:

public class TradeTrigger<W extends Window> extends Trigger<Object, W> {

    /**
     * 
     */
    private static final long serialVersionUID = 1L;
      
    private TradeTrigger() {
    }
    
    @Override
    public TriggerResult onElement(
            Object element,
            long timestamp,
            W window,
            
org.apache.flink.streaming.api.windowing.triggers.Trigger.TriggerContext ctx)
            throws Exception {
        
        ctx.registerEventTimeTimer(timestamp);
        return TriggerResult.CONTINUE;
        
    }

    @Override
    public TriggerResult onEventTime(
            long timestamp,
            W window,
            
org.apache.flink.streaming.api.windowing.triggers.Trigger.TriggerContext ctx)
            throws Exception {
    
    ValueState<Boolean> state = ctx.getPartitionedState(new 
ValueStateDescriptor<Boolean>("flag", Boolean.TYPE, false));
        
        if(state.value()==false){
            ctx.registerEventTimeTimer(timestamp+60000);
            state.update(true);
            return TriggerResult.FIRE;
        }else{
            System.out.println(""+state.value());
            ctx.registerEventTimeTimer(timestamp+20000);
            return TriggerResult.FIRE;
        }
    }

    @Override
    public TriggerResult onProcessingTime(
            long arg0,
            W arg1,
            
org.apache.flink.streaming.api.windowing.triggers.Trigger.TriggerContext arg2)
            throws Exception {
        // TODO Auto-generated method stub
        return TriggerResult.CONTINUE;
    }
    
     
    public static <W extends Window> TradeTrigger<W> of() {
        return new TradeTrigger<>();
    }

    
}

 Thanks and Regards,Piyush Shrivastava