> On Robert Vojcik wrote: > > http://www.vojcik.net/samsung-ssd-840-pro-performance-degradation/ > > Tuna som zas robil pred dlhsim casom uz test samsungu, mozes omrknut > aspon SMART hodnoty ktore sa ako menili a pozriet sa ako su na tom tvoje > disky.
Pozrel som na tie smart hodnoty a vidim toto: Device Model: M4-CT128M4SSD1 Firmware Version: 040H SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 100 100 050 Pre-fail Always - 0 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 9 Power_On_Hours 0x0032 100 100 001 Old_age Always - 16880 12 Power_Cycle_Count 0x0032 100 100 001 Old_age Always - 39 170 Grown_Failing_Block_Ct 0x0033 100 100 010 Pre-fail Always - 0 171 Program_Fail_Count 0x0032 100 100 001 Old_age Always - 0 172 Erase_Fail_Count 0x0032 100 100 001 Old_age Always - 0 173 Wear_Leveling_Count 0x0033 181 181 010 Pre-fail Always - 5277 174 Unexpect_Power_Loss_Ct 0x0032 100 100 001 Old_age Always - 35 181 Non4k_Aligned_Access 0x0022 100 100 001 Old_age Always - 3 0 3 183 SATA_Iface_Downshift 0x0032 100 100 001 Old_age Always - 0 184 End-to-End_Error 0x0033 100 100 050 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 001 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 001 Old_age Always - 0 189 Factory_Bad_Block_Ct 0x000e 100 100 001 Old_age Always - 86 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 0 195 Hardware_ECC_Recovered 0x003a 100 100 001 Old_age Always - 0 196 Reallocated_Event_Count 0x0032 100 100 001 Old_age Always - 0 197 Current_Pending_Sector 0x0032 100 100 001 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 100 001 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 100 100 001 Old_age Always - 0 202 Perc_Rated_Life_Used 0x0018 181 181 001 Old_age Offline - 175 206 Write_Error_Rate 0x000e 100 100 001 Old_age Always - 0 Nie som si isty, ale citam to spravne, ze disk je “po svojej zivnostnosti” na 175% (Perc_Rated_Life_Used)? A Wear_Leveling_Count 5277 je asi tiez velmi vysoka hodnota, ze? Druhy disk ma podobne hodnoty. Zaver je teda, ze je potreba vymenit disk? Disk z druheho serveru: Device Model: Samsung SSD 840 PRO Series Firmware Version: DXM05B0Q SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 9 Power_On_Hours 0x0032 097 097 000 Old_age Always - 10921 12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 38 177 Wear_Leveling_Count 0x0013 091 091 000 Pre-fail Always - 293 179 Used_Rsvd_Blk_Cnt_Tot 0x0013 100 100 010 Pre-fail Always - 0 181 Program_Fail_Cnt_Total 0x0032 100 100 010 Old_age Always - 0 182 Erase_Fail_Count_Total 0x0032 100 100 010 Old_age Always - 0 183 Runtime_Bad_Block 0x0013 100 100 010 Pre-fail Always - 0 187 Uncorrectable_Error_Cnt 0x0032 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0032 068 064 000 Old_age Always - 32 195 ECC_Error_Rate 0x001a 200 200 000 Old_age Always - 0 199 CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0 235 POR_Recovery_Count 0x0012 099 099 000 Old_age Always - 8 241 Total_LBAs_Written 0x0032 099 099 000 Old_age Always - 65876529478 Tento snad vyzera ok. Marian -- FreeBSD mailing list ([email protected]) http://www.freebsd.cz/listserv/listinfo/users-l