Hi All, My environment : (1) two node (active/passive) pacemaker cluster (2) SAN storage attached, add resource type "filesystem" (3) OS : RHEL 7.2
In old version of RHEL cluster, when attached SAN storage path lost(ex. filesystem fail), active node will trigger fence device to reboot itself. but when i use pacemaker on RHEL cluster, when i remove fiber cable on active node, all resources failover to passive node normally, but active node doesn't reboot. how to trigger fence reboot action when SAN filesystem lost? Thank a lot~~~ -- Kind regards, Albert Weng <https://www.avast.com/sig-email?utm_medium=email&utm_source=link&utm_campaign=sig-email&utm_content=webmail> 不含病毒。www.avast.com <https://www.avast.com/sig-email?utm_medium=email&utm_source=link&utm_campaign=sig-email&utm_content=webmail> <#DAB4FAD8-2DD7-40BB-A1B8-4E2AA1F9FDF2>
_______________________________________________ Users mailing list: Users@clusterlabs.org http://lists.clusterlabs.org/mailman/listinfo/users Project Home: http://www.clusterlabs.org Getting started: http://www.clusterlabs.org/doc/Cluster_from_Scratch.pdf Bugs: http://bugs.clusterlabs.org