Almost!
I'm not near an SGE install but there is one other file you need to
worry about. It's a text file that contains a simple integer value for
the "next" SGE job ID.
The file is called "jobseqnum" and it's found spool/qmaster/jobseqnum
You don't have to restore it from backup, just find the current file in
your system and edit it appropriately while SGE is not running.
Gowtham wrote:
Before rebuilding one of our clusters
(Rocks 5.4.2), I happened to backup
/opt/grigengine/default/common/
folder that contains a file 'accounting'
(~ 3.2MB, last job ID being 12924).
After the rebuild, I don't yet see
'accounting' in the aforementioned location.
So, would it be safe to assume that if I place
the backed up file in that location with
appropriate ownership and permissions, SGE
will continue numbering newer jobs from 12925?
Best,
g
--
Gowtham
Information Technology Services
Michigan Technological University
(906) 487/3593
http://www.it.mtu.edu/
_______________________________________________
users mailing list
[email protected]
https://gridengine.org/mailman/listinfo/users
_______________________________________________
users mailing list
[email protected]
https://gridengine.org/mailman/listinfo/users