On 04/18/2012 03:43 PM, Earl Lazarus wrote:
It would have been nice if I could change single resource values with <resource>=<value>.
You can, using qconf -mattr e.g. qconf -aattr exechost complex_values mem_free=7G node-r4-u32-c7-p15-o4 But as others have suggested, you should probably use a sensor instead. e.g. http://gridscheduler.sourceforge.net/howto/loadsensor.html Regards, -- Alex Chekholko [email protected] _______________________________________________ users mailing list [email protected] https://gridengine.org/mailman/listinfo/users