Joseph Farran <[email protected]> writes: > I am seeing some weird errors which may be related to this? > > 8/15/2012 14:47:01|listen|hpc|W|denied: client (login-1-1.local/execd/2808) > uses old GDI version 6.2u5 while qmaster uses newer version 8.1.1
I assume that was an old execd, which should have failed to start up or stopped communicating if it was already up, so you need to restart it with a consistent version. (The communication protocol changed from the 6.2u5 version when a new data type was added.) In case it's not clear, the upgrade procedure should be: stop the execds; stop the qmaster; install the new binaries; restart the master; restart the execds. -- Community Grid Engine: http://arc.liv.ac.uk/SGE/ _______________________________________________ users mailing list [email protected] https://gridengine.org/mailman/listinfo/users