Joseph Farran <[email protected]> writes:

> I am seeing some weird errors which may be related to this?
>
> 8/15/2012 14:47:01|listen|hpc|W|denied: client (login-1-1.local/execd/2808) 
> uses old GDI version 6.2u5 while qmaster uses newer version 8.1.1

I assume that was an old execd, which should have failed to start up or
stopped communicating if it was already up, so you need to restart it
with a consistent version.  (The communication protocol changed from the
6.2u5 version when a new data type was added.)

In case it's not clear, the upgrade procedure should be:  stop the
execds; stop the qmaster; install the new binaries; restart the master;
restart the execds.

-- 