Am 09.04.2013 um 10:04 schrieb William Hay:

> On 9 April 2013 05:52, Mahbube Rustaee <[email protected]> wrote:
> I use sge6.2u5. 
> How power can be control with scheduler as idle node be down then when a node 
> is needed be  on?
> thanks
> Grid engine doesn't have direct support for this AFAIK
>  
> You could have a cron job that checks if there are jobs running on a node or 
> queued for it and triggers the shutdown or power up as necessary.
> You could handle the shutdown from the jobs epilog and the power up from a 
> jsv.

Some time ago Fritz mentioned that SCM to control it is abandoned and Univa 
integrated something new to control it.

Nevertheless there are scripts like 
http://kimura.univ-montp2.fr/redmine/projects/cluster-tools/wiki/Greenginecode 
making a little bit of looking ahead. It's necessary to replace their calls to 
shutdown/start (originally ssh/WOL) with calls to ipmitool though to control it 
in a nicer way (Link "Repository" in the top row, other links are using a wrong 
port to download it). What's not working is advance reservation.

-- Reuti


> William
> _______________________________________________
> users mailing list
> [email protected]
> https://gridengine.org/mailman/listinfo/users


_______________________________________________
users mailing list
[email protected]
https://gridengine.org/mailman/listinfo/users

Reply via email to