Am 09.04.2013 um 10:52 schrieb Reuti:

> Am 09.04.2013 um 10:04 schrieb William Hay:
> 
>> On 9 April 2013 05:52, Mahbube Rustaee <[email protected]> wrote:
>> I use sge6.2u5. 
>> How power can be control with scheduler as idle node be down then when a 
>> node is needed be  on?
>> thanks
>> Grid engine doesn't have direct support for this AFAIK
>> 
>> You could have a cron job that checks if there are jobs running on a node or 
>> queued for it and triggers the shutdown or power up as necessary.
>> You could handle the shutdown from the jobs epilog and the power up from a 
>> jsv.
> 
> Some time ago Fritz mentioned that SCM to control it is abandoned and Univa 
> integrated something new to control it.

SDM, not SCM. - Reuti


> Nevertheless there are scripts like 
> http://kimura.univ-montp2.fr/redmine/projects/cluster-tools/wiki/Greenginecode
>  making a little bit of looking ahead. It's necessary to replace their calls 
> to shutdown/start (originally ssh/WOL) with calls to ipmitool though to 
> control it in a nicer way (Link "Repository" in the top row, other links are 
> using a wrong port to download it). What's not working is advance reservation.
> 
> -- Reuti
> 
> 
>> William
>> _______________________________________________
>> users mailing list
>> [email protected]
>> https://gridengine.org/mailman/listinfo/users
> 
> 
> _______________________________________________
> users mailing list
> [email protected]
> https://gridengine.org/mailman/listinfo/users


_______________________________________________
users mailing list
[email protected]
https://gridengine.org/mailman/listinfo/users