Hello! I have user test who send sms via http interface and two smsc (one via emi2 and another via Siemens ME45 phone, both work fine)
group = sendsms-user username = test password = ******** user-deny-ip = "*.*.*.*" user-allow-ip = "10.*.*.*" white-list = "http://127.0.0.1/html/white-list.txt" concatenation = true default-smsc = "MTS" max-messages = 2 and in the same time i saw in the access.log. 2002-07-15 21:15:18 Sent SMS [SMSC:MTSPH] [SVC:test] [ACT:] [from: +79165904505] [to:80951044112] [flags:0:1:0: 0:0] [msg:35:830 15.07 21:12 COB Before started^M] [udh:0:] 2002-07-15 21:15:24 Sent SMS [SMSC:MTSPH] [SVC:test] [ACT:] [from: +79165904505] [to:89021733067] [flags:1:1:0: 0:0] [msg:35:830 15.07 21:12 COB Before started^M] [udh:0:] 2002-07-15 21:21:22 Sent SMS [SMSC:MTS] [SVC:test] [ACT:] [from: +79165904505] [to:89026927820] [flags:0:1:0:0: 0] [msg:44:Session terminated MIDASIN 15/07/02 21:12:41] [udh:0:] 2002-07-15 21:21:33 Sent SMS [SMSC:MTS] [SVC:test] [ACT:] [from: +79165904505] [to:89026927820] [flags:0:1:0:0: 0] [msg:44:Session terminated MIDASOU 15/07/02 21:13:01] [udh:0:] That's wrong? Why default-smsc not in use? P.S. http request dos'n contain smsc parameter. Thanks for advise. with best wishes German Aksenov phone: (095)258-7258 ext. 7836