I found some more headers:
00 51 :UDHI & SUBMIT 00 :MR 0C :Dest Address Len 91 :Dest Address Type 94 :Dest Address goes here... xx xx xx xx xx 00 :Protocol ID 04 :DCS (0x08 is alos tried) A7 :? 80 :UDL 06 :UDHL 05 :IEI - Port Address (16bit) 04 :IEIL/LEN 0B :Dest Port (Wap Push) 84 :Dest Port 23 :Org Port F0 :Org Port 04 :TID (Push ID) 06 :PDU Type (PUSH) 17 :HeaderLen AE :Content Type 96 : 6C6F63616C686F73743A3930383000AF 808DCFB48002056A0045C60C03776170 2E696F626F782E666900110331407769 72616C2E636F6D00080AC30720000625 15231510C30420030630010357616E74 20746F20746573742061206665746368 3F000101 This message is generated by Kannel when using PPG_Test with the control and content XML examples from the docs. Kannel messed up the UDL (it was 70) and I got an "UDL doesn't match length of user data" from my Siemens m20 gsm modem. So I calculated the right UDL (7bit) which is 80 and now the Siemens m20 throws an error 500 (unknown error), which isn't really helpful ;o) Maybe someone finds the error in my message, I don't know for example what the A7 value is... greetings, Ralph