Hi Jaakko,

The Version is:

AT+gmr
V 7.21
09-04-02
TME-3
(c) NMP.

Thanks,
Rajkumar Farkiya

----- Original Message -----
From: "Jaakko Heikkil�" <[EMAIL PROTECTED]>
To: "Rajkumar Farkiya" <[EMAIL PROTECTED]>
Cc: <[EMAIL PROTECTED]>
Sent: Wednesday, August 27, 2003 5:57 PM
Subject: Re: Nokia Premicell


> Have you noticed terminal lights to go out for a while, or have you
> disconnected power cable before terminal stopped working?
>
> Do you know your terminal's software version? You can get it with
> AT-command "at+gmr" or with "Nokia GSM Connectivity Terminal
> Configurator" (available only for Window$).
>
> On Wed, 2003-08-27 at 14:57, Rajkumar Farkiya wrote:
> > Hi Jaakko,
> >
> > I tried the same configuration but after delivering few messages it will
> > stop
> > working.  Kannel shows that everything is perfect and display this after
> > every
> > 60 seconds.
> >
> > 2003-09-07 22:49:16 [6] DEBUG: AT2[/dev/ttyS0]: --> AT+CPMS="SM"^M
> > 2003-09-07 22:49:16 [6] DEBUG: AT2[/dev/ttyS0]: <-- +CPMS:
0,15,0,15,0,35
> > 2003-09-07 22:49:16 [6] DEBUG: AT2[/dev/ttyS0]: <-- OK
> >
> > But the incoming message will not coming to kannel. If i rang on the
same
> > number
> > it shows the RING message but not receving SMS Messages.
> >
> > Thanks,
> > Rajkumar Farkiya
> >
> > ----- Original Message -----
> > From: "Jaakko Heikkil�" <[EMAIL PROTECTED]>
> > To: <[EMAIL PROTECTED]>
> > Sent: Wednesday, August 27, 2003 5:17 PM
> > Subject: Re: Nokia Premicell
> >
> >
> > Hi Rajkumar,
> >
> > Nokia 30 does not work if you configure it as a "Premicell".
> > First you should upgrade Kannel to the latest development release
> > (1.3.1) if you are not already using it.
> >
> > With development release this configuration should work:
> >
> > group = smsc
> > smsc = at2
> > modemtype = nokia30
> > #smsc-id = my_modem
> > my-number = +358XXXXXXX
> > device = "/dev/ttyS0"
> > speed = 115200
> > # Empties SIMM or terminal memory for the messages
> > sim-buffering = true
> > # Send keep-alive message for the modem every 60 seconds
> > keepalive = 60
> >
> > group = modems
> > id = nokia30
> > name = "Nokia 30"
> > detect-string = "Nokia 30"
> > # This speed does not work with Kannel version <= 1.2.1
> > speed = 115200
> > keepalive-cmd = "AT+CBC;+CSQ"
> > # SIM buffering storage: "SM" SIM card or "ME" Mobile equipment memory
> > message-storage = "SM"
> > enable-mms = true
> >
> >
> > On Wed, 2003-08-27 at 14:01, [EMAIL PROTECTED] wrote:
> > > From: "Rajkumar Farkiya" <[EMAIL PROTECTED]>
> > > To: "Kannel" <[EMAIL PROTECTED]>
> > > Cc: <[EMAIL PROTECTED]>
> > > Subject: Nokia Premicell
> > > Date: Tue, 26 Aug 2003 18:50:10 +0530
> > >
> > > This is a multi-part message in MIME format.
> > >
> > > ------=_NextPart_000_1158_01C36C02.E0633BC0
> > > Content-Type: text/plain;
> > > charset="iso-8859-1"
> > > Content-Transfer-Encoding: quoted-printable
> > >
> > > Hi All,
> > >
> > > I am configuring Nokia 30 GSM Modem with following Default =
> > > Configuration:
> > >
> > > group =3D smsc
> > > smsc =3D at2
> > > modemtype =3D premicell
> > > device =3D /dev/ttyS0
> > > pin =3D 0000
> > > sms-center=3D+91xxxxxxxxxx
> > > my-number =3D xxxxxxxxxx
> > > speed=3D9600
> > > keepalive=3D60
> > >
> > >
> > > group =3D modems
> > > id=3Dpremicell
> > > name=3Dm30
> > > speed=3D9600
> > >
> > > The kannel works fine for few messages and after that stop receiving
any =
> > > messages from
> > > modem if we call on the number it will display RING message but for
SMS =
> > > messages it stops=20
> > > working after 10-15 messages without error message.
> > >
> > > There is some configuration mistake. Please let me know how to
configure =
> > > the proper settings
> > > so that the messages keep coming and respond by the Kannel.
> > >
> > > Thanks in advance,
> > > Rajkumar Farkiya
> >
> > --
> > -----------------------------------------------------
> > Jaakko Heikkil�                 GSM: +358-40-7637 118
> >
> > Bluepoint Ltd                 http://www.bluepoint.fi
> > Teknologiantie 10 B              Tel: +358-8-551 5095
> > FIN-90570 Oulu, Finland          Fax: +358-8-551 5096
> >
> >
> --
> -----------------------------------------------------
> Jaakko Heikkil�                 GSM: +358-40-7637 118
>
> Bluepoint Ltd                 http://www.bluepoint.fi
> Teknologiantie 10 B              Tel: +358-8-551 5095
> FIN-90570 Oulu, Finland          Fax: +358-8-551 5096
>
>
>


Reply via email to