Hi:
I guess your are received '+' or any character prefix.
You can solve this in your smsc group:
address-range = "^99011$"
source-addr-ton = 5
source-addr-npi = 0
source-addr-autodetect = true
dest-addr-ton = 4
dest-addr-npi = 0
bind-addr-ton = 0
bind-addr-npi = 0
msg-id-type = 0x01
Samir Ghodasara wrote:
Hi,
i am new user for Kannel and currently trying to configure kannel to
receive the message for give short code.
I configure kannel for two different SMSC for same short code.
I am able to receive message from one SMSC,but while using other SMSC
mobile i am getting
"Mallformed addr `****', expected at least 7 digits." at Bear box.
Conf which i am using..
gateway-1.4.1
source-addr-ton=1
source-addr-npi=1
dest-addr-ton=1
dest-addr-npi=1
transceiver-mode=true
I am really confuse that it is working for one SMSC and not working
for anhother SMSC.
Waiting for your valuable response.
Thanks & Regards,
Samir.
--
Jean-Claude Adams
Encargado de Sistemas
PICO S.A.CI.
Tel. +595 21 665052
Cel. +595 981 833415
email: [EMAIL PROTECTED]