Hi,
Please address users list for such questions, not devel.
It seems that your SMSc cannot distinguish between the different
connections, and sent the submit_sm_resp to the wrong one. Are you trying to
do load balancing? If so you should use the same smsc-id for both
connections.
BR,
Nikos
----- Original Message -----
From: Mohammed Saleem
To: kannel_dev_mailinglist
Sent: Tuesday, November 16, 2010 10:38 AM
Subject: SMPP wrong sequence number?
Hello Kannellers
I've got a warning like this
WARNING: SMPP[XXX]: SMSC sent submit_sm_resp with wrong sequence number
0x00002848
but actually I couldn't understand whats wrong, can anyone explain whats the
issue?
I am defining 2 instances of this connections with max-pending-submits=25
for each connection, both connections reports this warning too much in the
log, is there something I am doing wrong here? or is there a problem at the
carrier's side that I have to report and let them fix it?
Thanks
Best Regards,
Mohammed M I Sleem
http://www.abusleem.net
http://www.freakle.com - The Search Freak
http://www.colorle.com - color your Google search