Hi,

Please address users list for such questions, not devel.

It seems that your SMSc cannot distinguish between the different connections, and sent the submit_sm_resp to the wrong one. Are you trying to do load balancing? If so you should use the same smsc-id for both connections.

BR,
Nikos
----- Original Message ----- From: Mohammed Saleem
To: kannel_dev_mailinglist
Sent: Tuesday, November 16, 2010 10:38 AM
Subject: SMPP wrong sequence number?


Hello Kannellers


I've got a warning like this

WARNING: SMPP[XXX]: SMSC sent submit_sm_resp with wrong sequence number 0x00002848

but actually I couldn't understand whats wrong, can anyone explain whats the issue?

I am defining 2 instances of this connections with max-pending-submits=25 for each connection, both connections reports this warning too much in the log, is there something I am doing wrong here? or is there a problem at the carrier's side that I have to report and let them fix it?


Thanks





Best Regards,
Mohammed M I Sleem
http://www.abusleem.net

http://www.freakle.com - The Search Freak

http://www.colorle.com - color your Google search

Reply via email to