Well, it seems now you are sending fine.
The problem is not with the SMPP spec, just some particular SMScs who can't
keep their sockets straight! This could have worked also if you had
different accounts for each connection.
BR,
Nikos
----- Original Message -----
From: Mohammed Saleem
To: Nikos Balkanas
Cc: [email protected]
Sent: Tuesday, November 16, 2010 1:05 PM
Subject: Re: SMPP wrong sequence number?
hmmm,
first of all I couldn't send to the users list, they replied to me that I
dont have access !!
second, I had this problem with multiple connections, my DLRs got dismatched
yes, but I resolved this by modifying the source and deleted the SMSC-ID
match to become only using (msisdn) the dest and the ts (foreign id) and it
works fine with me
but the question is, is there anything wrong with duplicating SMPP
connections with different smsc-ids other than the DLR mismatching? Thanks
Nikos
Best Regards,
Mohammed M I Sleem
http://www.abusleem.net
http://www.freakle.com - The Search Freak
http://www.colorle.com - color your Google search
2010/11/16 Nikos Balkanas <[email protected]>
Yes, otherwise your DLRs will continue to get mismatched.
BR,
Nikos
----- Original Message ----- From: Mohammed Saleem
To: Nikos Balkanas
Cc: [email protected]
Sent: Tuesday, November 16, 2010 12:01 PM
Subject: Re: SMPP wrong sequence number?
Yes I am doing load balancing
my carrier gave me permission to connect more than one instance for each
SMPP account, so I use the following SMSC connections:
connection 1
smsc-id=OP_000
connection 2
smsc-id = OP_002
both smsc connections have the same connection properties (username,
password,...etc)
Are you saying that I have to name both connections with the same smsc-id?
is this valid in Kannel? please advise
Thanks
Best Regards,
Mohammed M I Sleem
http://www.abusleem.net
http://www.freakle.com - The Search Freak
http://www.colorle.com - color your Google search
2010/11/16 Nikos Balkanas <[email protected]>
Hi,
Please address users list for such questions, not devel.
It seems that your SMSc cannot distinguish between the different
connections, and sent the submit_sm_resp to the wrong one. Are you trying to
do load balancing? If so you should use the same smsc-id for both
connections.
BR,
Nikos
----- Original Message ----- From: Mohammed Saleem
To: kannel_dev_mailinglist
Sent: Tuesday, November 16, 2010 10:38 AM
Subject: SMPP wrong sequence number?
Hello Kannellers
I've got a warning like this
WARNING: SMPP[XXX]: SMSC sent submit_sm_resp with wrong sequence number
0x00002848
but actually I couldn't understand whats wrong, can anyone explain whats the
issue?
I am defining 2 instances of this connections with max-pending-submits=25
for each connection, both connections reports this warning too much in the
log, is there something I am doing wrong here? or is there a problem at the
carrier's side that I have to report and let them fix it?
Thanks
Best Regards,
Mohammed M I Sleem
http://www.abusleem.net
http://www.freakle.com - The Search Freak
http://www.colorle.com - color your Google search